Pix syslog meldingen ( Messages 106001 to 105020 )

In Cisco , Pix Firewall


Syslog meldingen als hulp bij het troubleshooten van problemen.


Messages 101001 to 105020

 

Note The messages shown in this guide only apply to PIX Firewall version 4.4(1) and later. When a number is skipped from a sequence, for example, 106004 or 110001, the message is no longer in the PIX Firewall code.



Log Message %PIX-1-101001: (Primary) Failover cable OK.


Uitleg:
This is a failover message. This message reports that the failover cable is present and functioning correctly. '(Primary)' can be either Primary or Secondary.



Recommended Action:
:
None required.




Log Message %PIX-1-101002: (Primary) Bad failover cable.


Uitleg:

This is a failover message. This message reports that the failover cable is present but not functioning correctly. '(Primary)' can be either Primary or Secondary.



Recommended Action:
:
Replace the failover cable.
Log Message %PIX-1-101003: (Primary) Failover cable not connected (this unit).
Log Message %PIX-1-101004: (Primary) Failover cable not connected (other unit).
Uitleg:
Both instances are failover messages.
These messages are logged when failover mode has been enabled, but the failover cable is not connected to one unit of the failover pair. '(Primary)' can be either Primary or Secondary.


Recommended Action:
Connect the failover cable to both units of the failover pair.


Log Message %PIX-1-101005: (Primary) Error reading failover cable status.
Uitleg:
This is a failover message.
This message is logged if the failover cable is connected, but the primary unit is unable to determine its status. '(Primary)' can be either Primary or Secondary.



Recommended Action:
Replace the cable.


Log Message %PIX-1-102001: (Primary) Power failure/System reload other side.

Uitleg:
This is a failover message. This message is logged if the primary unit detects a power failure on the other unit. '(Primary)' can be either Primary or Secondary.

Recommended Action:
Verify that the secondary unit is powered on and that power cables are properly connected.


Log Message %PIX-1-103001: (Primary) No response from other firewall.

Uitleg:
This is a failover message. This message is logged if the primary unit is unable to communicate with the secondary unit over the failover cable. '(Primary)' can be either Primary or Secondary.

Recommended Action:
Verify that the secondary unit has the exact same hardware, software version level, and configuration as the primary unit.

Log Message %PIX-1-103002: (Primary) Other firewall network interface interface_number OK.

Uitleg:
This is a failover message. This message is logged when the specified network interface, which was previously reported as failed, begins functioning correctly. '(Primary)' can be either Primary or Secondary.

Recommended Action:
None required.


Log Message %PIX-1-103003: (Primary) Other firewall network interface interface_number failed.

Uitleg:
This is a failover message. This message is logged if the primary unit detects a bad network interface on the secondary unit. '(Primary)' can be either Primary or Secondary.

Recommended Action:
Check the network connections on the secondary unit. Also, check the network hub connection. If necessary, replace the failed network interface.


Log Message %PIX-1-103004: (Primary) Other firewall reports this firewall failed.

Uitleg:
This is a failover message. This message is logged if the primary unit receives a message from the secondary unit indicating that the primary has failed. '(Primary)' can be either Primary or Secondary.

Recommended Action:
Verify the status of the primary unit.

Log Message %PIX-1-103005: (Primary) Other firewall reporting failure.
Uitleg:
This is a failover message. This message is logged if the secondary unit reports a failure to the primary unit. '(Primary)' can be either Primary or Secondary.

Recommended Action:
Verify the status of the failover unit with the show failover command.

Log Message %PIX-1-104001: (Primary) Switching to ACTIVE (cause: reason).

Log Message %PIX-1-104002: (Primary) Switching to STNDBY.
Uitleg:
Both instances are failover messages. These messages usually are logged when you force the pair to switch roles, either by entering the failover active command on the secondary unit, or the no failover active command on the primary unit. '(Primary)' can be either Primary or Secondary.

Recommended Action:
If the message occurs because of manual intervention, no action is required. Otherwise, use the cause reported by the secondary unit to verify the status of both units of the pair.

Log Message %PIX-1-104003: (Primary) Switching to FAILED.
Uitleg:
This is a failover message. This message is logged when the primary or secondary unit fails. '(Primary)' can be either Primary or Secondary.

Recommended Action:
Check the system log messages for the primary unit for an indication of the nature of the problem (see message 104001).

Log Message %PIX-1-104004: (Primary) Switching to OK.
Uitleg:
This is a failover message. This message is logged when a previously failed unit now reports that it is operating again. '(Primary)' can be either Primary or Secondary.

Recommended Action:
None required.

Log Message %PIX-1-105001: (Primary) Disabling failover.
Uitleg:
This is a failover message. This message is logged when you enter the no failover command on the console. '(Primary)' can be either Primary or Secondary.

Recommended Action:
None required.

Log Message %PIX-1-105002: (Primary) Enabling failover.
Uitleg:
This is a failover message. This message is logged when you enter the failover command with no arguments on the console, after having previously disabled failover. '(Primary)' can be either Primary or Secondary.

Recommended Action:
None required.

Log Message %PIX-1-105003: (Primary) Monitoring on interface interface_number waiting.
Uitleg:
This is a failover message. The PIX Firewall is testing the specified network interface with the other unit of the failover pair. '(Primary)' can be either Primary or Secondary.

Recommended Action:
None required. The PIX Firewall monitors its network interfaces frequently during normal operations.

Log Message %PIX-1-105004: (Primary) Monitoring on interface interface_number normal.
Uitleg:
This is a failover message. The test of the specified network interface was successful. '(Primary)' can be either Primary or Secondary.

Recommended Action:
None required.

Log Message %PIX-1-105005: (Primary) Lost failover communications with mate on interface interface_number.
Uitleg:
This is a failover message. This message is logged if this unit of the failover pair can no longer communicate with the other unit of the pair. '(Primary)' can be either Primary or Secondary.

Recommended Action:
Verify that the network connected to the specified interface is functioning correctly.

Log Message %PIX-1-105006: (Primary) Link status `Up' on interface interface_number.

Log Message %PIX-1-105007: (Primary) Link status `Down' on interface interface_number.
Uitleg:
Both instances are failover messages. These messages report the results of monitoring the link status of the specified interface. '(Primary)' can be either Primary or Secondary.

Recommended Action:
If the link status is down, verify that the network connected to the specified interface is operating correctly.

Log Message %PIX-1-105008: (Primary) Testing interface interface_number.
Uitleg:
This is a failover message. This message is logged when the PIX Firewall tests a specified network interface. This testing is performed only if the PIX Firewall fails to receive a message from the Standby unit on that interface after the expected interval. '(Primary)' can be either Primary or Secondary.

Recommended Action:
None required.

Log Message %PIX-1-105009: (Primary) Testing interface interface_number result.
Uitleg:
This is a failover message. This message reports the result (either 'pass' or 'fail') of a previous inter

RSS Twitter e-mail